Activating call accounting for Ericsson BP 250
Aucune traduction disponible

Ericsson

  Ericsson BP 250


6006 - Device type: 7 (unspecified terminal/printer)

6007 - Character set: 0 (no conversion)

6009 - IOU (except CPU-D4) Baud rate: 10 (2400 Baud)

6009 - IOU (CPU-D4) Baud rate: 10 (2400 Baud)

6009 - SMU (except CPU-D4) Baud rate: 8 (1200 Baud)

6009 - SMU (CPU-D4) Baud rate: 10 (2400 Baud)

6011 - Autoselect allowed: Yes (optional)

6017 - Mode selection for serial interface - should be RS-232

6101 - Set year month day to : YYMMDD

6102 - Set day of week: 1 - Sunday, 7 - Saturday

6103 - Set hour minute second: HHMMSS

6104 - 12h mode, display - Set it to N for 24 mode

6201 - Log internal calls? - Set it to YES

6202 - Log incoming calls? - Set it to YES

6203 - Block log output? - Set it to YES

6204 - Digits to log - Set it to NO

6205 - Bar outgoing calls for guest - Set it to Yes if you want to stop guest making calls while the pbx memory is full. Usefull for hotels. (optional)

6301 - Log outgoing calls? - Set it to YES

6302 - Log duration time - Set it to 0 because you can configure it in the application.

6303 - Log minimum meter pulses - Should set it to 0

6304 - Bar outgoing calls? - Set it to YES if you want to stop the outgoing calls while the calls storage if out of order and the pbx memory is full. (optional)

6305 - Dialed number: suppress - Set it to 0 unless you want to strip the last n digits from the dialed number for security reasons.

6306 - Log dialed numbers beginning with 0 - Set it to YES.

6307 - Log dialed numbers beginning with 1 - Set it to YES.

6308 - Log dialed numbers beginning with 2 - Set it to YES.

6309 - Log dialed numbers beginning with 3 - Set it to YES.

6310 - Log dialed numbers beginning with 4 - Set it to YES.

6311 - Log dialed numbers beginning with 5 - Set it to YES.

6312 - Log dialed numbers beginning with 6 - Set it to YES.

6313 - Log dialed numbers beginning with 7 - Set it to YES.

6314 - Log dialed numbers beginning with 8 - Set it to YES.

6315 - Log dialed numbers beginning with 9 - Set it to YES.

6332 - Log minimum cost - Set it 0

6403 - Format table - Format 00-29, Set it to 01 and select Ericsson MD110 in app.

6404 - Lines per page - Set it to 0

6402 - Automatic I/O activation - Set it to 1 minute. (0 means disabled)

6701 - I/O Port - Value ppiii where pp is board position and iii is individual number of a V24 (IO unit) port.

6702 - Lines/page - Set it to 0
Dernière mise à jour : ( 05-02-2007 )
 
< Précédent   Suivant >